Additionally, paste this code immediately after the opening tag:

17th Edition Cable Sizer

Cable size calculation done completely and accurately in seconds, providing detailed results with all correcti...

$ 3.08

Store review

Cable size calculation done completely and accurately in seconds, providing detailed results with all correction factors used. Perform an automatic calculation where the circuit is sized automatically or enter fixed sizes to run a calculation check on an existing design. Created for electrical engineers, electricians and designers. Suitable for Industrial, Commercial or Domestic Low Voltage Circuits.

Simple, fast and reliable. 17th edition cable sizer performs cable Calculation for AC circuits in line with British Standard 7671:2008(2011) IEE Wiring regulations, without having to lookup the relevant tables.

Watch the video for a full demonstration of the features available.

Simply enter the circuit parameters, hit calculate, and 17th edition cable sizer does the work for you by selecting the correct cable based on current carrying capacity, earth loop impedance, voltage drop and adiabatic check. If you want to change a parameter, go back and modify it, then re-calculate to see the difference.

Alternatively set the cable size and number of conductors in parallel and perform a calculation to check an existing design.

Results are presented in a simple format with all rating factors given, which can then be sent by email.

All rating factors are considered, all installation methods available, power factor and conductor operating temperatures are incorporated into the calculation. Parallel cables are supported automatically if current exceeds maximum available for cable type.

R1+R2, Zs and Fault currents are calculated and displayed. Automatic checks of Zs are performed for MCB's, RCBO's and BS3036 fuses.

Earth can be set to use Steel wire armouring or Separate conductor where applicable.

Typical external earth loop impedances can be used based on public supply type or transformer size.

The following cables are supported (in every available size)

BS6724 Single Core and Multicore Armoured XLPE Copper/Aluminium
BS5467 Single Core and Multicore Armoured PVC Copper/Aluminium
Flat Twin and earth XLPE
Flat Twin and earth PVC
6491B Single core XLPE Copper/Aluminium
6491X Single core PVC Copper/Aluminium

The following protective devices can be used

BS EN 60898 MCB Types B, C and D
BS EN 60947-2 MCCB
BS EN 61009-1 RCBO 30mA
BS 88 HRC Fuses
BS 3036 Rewireable Fuse
BS 1361 Cartridge Fuse

All the data is stored locally on the phone so no Internet connection is ever required.

If you like this app, please rate it. Also if you find any issues or have any suggestions for new features, please contact me by email [elecengsoft@gmail.com](mailto:elecengsoft@gmail.com).

See our other app, Cable Installer, for cable, cleats and gland sizes.

Keywords 7671, Cable Sizing, Cable Calculator, ProDesign

Store rating

4

out of

15 reviews

Last update

Sept. 17, 2013

Read more